Performance: >Measurement Range: to 25,000ft. or 12,500ft; selectable >Resolution: 12ft >Accuracy: +- 20ft. over full range >Cloud Layers: up to four, base and depth >Measurement cycle: configurable to 30, 60 or 120 sec sampling interval; can switch to 180 sec interval when no clouds detected.
Principal of Operation: >LIDAR: pulsed diode, InGaAs >Wavelength: 905nm +- 10nm >Pulse Width: 50nm >Collector type: Si Avalanche photodiode, variable gain, temperature compensated. >Optics: side-by-side optical channels
Safety: >Laser Safety: FDA Class 1, 21 CFR1040
Electrical: >Power: 95-240 VAC >Frequency: 47-64 Hz >Power Consumption: electronics - 100W max, heaters - 600W max
Mechanical: >Dimensions: ceilometer - 19" H x 9" D x 16" W, with heater - 27" H x 20" D x 16" W > Weight: ceilometer - 43lbs, heater - 18lbs >Mounting: single leg pedestal; 21/2" pipe, unistrut mounted
Environmental: >Operation: -40°C to +60°C >Storage: -50°C to +70°C >Relative Humidity: 0-100%, condensing >Enclosure: Ceilometer - NEMA 4X stainless steel, heater - aluminum
Commnication: >RS-232: cloud detection, vertical visibility, sky condition algorithm, system status.
|