Performance: >Measurement range: 0 to 25000 ft (acquisition time 15s) >Resolution: 50ft >Range gates: pulsed diode, InGaAs MOCVD >Wavelength 905nm >Eye Saftey: Class WM EN60825, Class 1 12CRF1040 >Meaurement cycle: programmable 15 to 120 seconds
Electrical: >Power: 100/115/230 VAC, max. 400W inc. heating, +- 10%, 45 to 60 Hz >Interfaces: Two serial lines, RS-232 RS-485, RS-422, Modem Bell/ITU-T 300 to 9,600Bd, Modem Bell, Bell 212A, ITU-T.21, V.22, V22bis
Data Messages: >cloud hits and status only >cloud hits, status, internal monitoring data and full backscatter profile >sky condition
Output Options: >DD50 digital display >Graphic PC display software CT-VIEW >DR23 chart recoder
Mechanical: >Dimensions: total - 1335 H x 447 W x 378 D mm, unit - 672 H x 308 W x 244 D mm >Weight: total - 35 kg, measurement unit - 16 kg >Installation to the single-leg pedestal as standard, allowing tilting between -15 +90° >Automatic window heater and protection shield
Environmental: >Temperature range: -50 to +60°C >Humidity: 0 to 100% >Protection class: IP65 >Vibration during operation: 0.5 G, 10 to 500 Hz (IEC68-2-6 FC) >EMC/EMI: CISP 22B/FCC 15 Part J or IEC 801-4 level 3 >Static: 8KV (IEC801-2 level 4) >Wind: Gusting up to 60m/s >Electrical saftey: EN60950
|