| | The air temperature and humidity probe OMC-406 provides accurate and precise measurements of both temperature and humidity in two 420mA outputs. The temperature sensor within the probe is a Pt 100 element, while the principle of humidity measurement is based on a capacitive measuring device. | | 
 |
|
Please call or email us for an updated quote on this item |
Technical details |
| | Humidity Measuring range 0 to 100% RH Accuracy at 23 degree C <+/- 1.5% RH between 10 to 95% Reproducibility <+/- 0.5% RH Hysteresis for a 4hr cycle <1% RH Time constant at 23 degree C <15sec Temperature error +/- 0.5% RH Linear output 4 to 20mA = 0 to 100%
|
|
| | Temperature Measuring range -40 to 60 degree C Accuracy <+/- 0.5 degree C Reproducibility <+/- 0.1 degree C Time constant 15sec Linear output 4 to 20mA Measuring system Pt100, 1/3 DIN
|
|
| | General Power supply 10 to 30V dc, 50mA Protection of the sensors wire mesh filter Dimensions: 265mm length, 25mm diameter Net weight 0.17kg
|
|